Say this
Read it out, or put it in your own words. Stop and point at the real thing on this site wherever you can.
1. What is a confined space
A confined space is any enclosed or partly enclosed place where dangerous gas, fumes or dust can build up or where there may not be enough oxygen. On our jobs that means manholes and sewers, septic and conservancy tanks, water tanks and reservoirs, sumps, deep pits and chambers, large pipes and ducts, and sometimes a closed-in roof void or basement. If it has a small way in and out, and poor air movement, treat it as a confined space.
2. Why it kills
You cannot trust your nose. Some deadly gases have no smell, and others knock out your sense of smell. Sewers and tanks can hold gas from rotting waste. A petrol pump, generator or gas torch running in or near the space can fill it with fumes, and oxygen can be used up just by rust or rotting material. A person can collapse within moments, without warning.
3. Nobody goes in without permission
Nobody enters a confined space unless the supervisor has arranged it. Before entry, a competent person must test the air and confirm in writing that it is safe and will stay safe for the work. Pipes and valves that could let in water, sewage or gas must be blocked off or locked. If the air cannot be made safe, entry is only with breathing apparatus, a harness and line, and a trained person standing by outside.
4. Never run in to help
If someone inside collapses or stops answering, do not go in after them. Many deaths in confined spaces are rescuers who went in to help a friend. Shout for help, call the emergency numbers on the site board, and use the line attached to their harness to pull them out from outside if it is set up. Only trained people with breathing apparatus may go in.
5. Keep the space safe
Never run a generator, compressor, petrol pump or gas heater inside or near the opening. Keep the standby person at the entrance the whole time, not off fetching tools. Barricade open manholes and tanks so nobody falls in. If anyone inside feels dizzy, gets a headache or feels sick, everyone gets out at once and reports it.
Check on site today
- Is there any manhole, tank, sump, pit, pipe or chamber on this site that someone may need to enter today?
- Has the air been tested by a competent person, and is the written permission to enter on site?
- Are the pipes, valves and inlets that could flood the space blocked off or locked?
- Who is the standby person, are they trained in resuscitation, and is the harness, line and rescue equipment ready?
- Are generators, pumps and compressors well away from the opening?
- Are open manholes and tank openings covered or barricaded?
Ask the crew
Open questions get people talking. Listen to the answers: they tell you what's really happening on site.
- Which places on this site or our recent jobs would you call a confined space?
- What would you do if your mate went quiet down a manhole?
- Why is it dangerous to run a petrol pump in a pit or tank?
- Have you ever been asked to go into a tank or manhole without the air being tested? What happened?
Protective equipment for this job
- Harness with a rescue line attended from outside
- Approved breathing apparatus where the air cannot be made safe
- Gas detector used by a competent person
- Gloves, boots and overalls suited to the contents (for example sewage)
What the law says
In our own words. Follow the links for the full wording.
- General Safety Regulations, 1986, regulation 5: Work in confined spacesA confined space may be entered only after a competent person has tested and evaluated the air and certified in writing that it is safe and will stay safe for the work. Otherwise the space must be purged and ventilated and isolated from pipes and openings by blanking or locked valves; if the air still cannot be made safe, entrants must use approved breathing apparatus and a harness with a line attended from outside, with at least one person trained in resuscitation standing by at the entrance with breathing and resuscitation equipment. Everyone must leave on completion, and the same rules apply to work right next to the space.Read on 21 November 2026
- General Safety Regulations, 1986, regulation 1: Definitions ("confined space")Defines a confined space as an enclosed, restricted or limited space where a hazardous substance may build up or the air may lack oxygen, including chambers, tunnels, pipes, pits, sewers, containers, pumps and sumps.Read on 21 November 2026
- General Safety Regulations, 1986, regulation 9: Welding, flame cutting, soldering and similar operationsSubregulation (2): welding or flame cutting in a confined space is allowed only with effective ventilation, or with masks or hoods supplying safe air to breathe.Read on 21 November 2026
Sign the register